Previous
Next
SKB

SKB Lead Acid Battery 12V 9.0Ah SK12-9 - UPS Replacement Battery (Boxed)

SKU 39257 Brand SKB EAN13 8023389051472
SKB SK12-9 is a 12V 9.0Ah lead-acid replacement battery for UPS systems. Features 6 cells, 204W power output (15min), 6.3mm Faston terminals, and AGM technology for reliable standby power backup.
UPS & Power Backup - Product Type Replacement Battery
UPS & Power Backup - Power Output (Watts) Under 500 W

The SKB SK12-9 is a 12V 9.0Ah lead-acid replacement battery specifically designed for uninterruptible power supply (UPS) systems and standby power applications. This valve-regulated lead-acid (VRLA) battery utilizes AGM (Absorbent Glass Mat) technology, providing reliable and maintenance-free operation with an expected service life of 10 years under EUROBAT classification standards.

Built with 6 cells in series, this battery delivers 204W of power output at 15-minute discharge rates, making it suitable for backup power in computer systems, networking equipment, and emergency lighting. The battery features 6.3mm Faston terminals with a 4-terminal layout for flexible installation options. It operates across a wide temperature range (-10°C to +60°C for discharge, -20°C to +60°C for charging and storage) and supports both standby (buffer) charging at 13.5-13.8V and cyclic charging at 14.4-15.0V.

Compact dimensions of 151×65×95mm and a lightweight design of 2.60kg make this battery easy to integrate into existing UPS systems. The ABS high-impact plastic container ensures durability and safety, while the maximum discharge current capability of 130A (5-second burst) provides reliable performance during power transitions.

  • Voltage: 12V DC
  • Capacity: 9.0Ah
  • Power Output: 204W (15-minute rating)
  • Number of Cells: 6
  • Terminal Type: 6.3mm Faston connectors
  • Dimensions: 151×65×95mm (L×W×H)
  • Weight: 2.60kg
  • Technology: Valve-regulated lead-acid (VRLA) with AGM
  • Buffer Charging Voltage: 13.5-13.8V DC
  • Cyclic Charging Voltage: 14.4-15.0V DC
  • Standard Charging Current: 2.70A
  • Maximum Discharge Current: 130A (5-second burst)
  • Operating Temperature: -10°C to +60°C
  • Storage Temperature: -20°C to +60°C
  • Expected Service Life: 10 years (EUROBAT Standard Commercial)
Voltage12 Vdc
Capacity9.0 Ah
Number of Cells6
Battery Power (15min)204 W
Power per Cell (15min)34 W
Terminal Type6.3 mm Faston
Terminal Layout4-terminal
Dimensions (L×W×H)151×65×95 mm
Dimensions with Height Tolerance151×65×101 mm (HT)
Weight2.60 kg
TechnologyValve-regulated lead-acid (VRLA) with AGM
Buffer Charging Voltage13.5 - 13.8 Vdc
Cyclic Charging Voltage14.4 - 15.0 Vdc
Standard Charging Current2.70 A
Maximum Discharge Current (5 sec)130 A
Discharge Temperature Range-10 ~ +60 °C
Charging Temperature Range-20 ~ +60 °C
Storage Temperature Range-20 ~ +60 °C
EUROBAT Classification3 - 5 years Standard Commercial (10-year expected life for standby)
Container MaterialABS - HB (High-Impact Plastic)
ApplicationUPS (Uninterruptible Power Supply) standby power
Minimum Discharge Voltage10.50 V (for 12V battery)